The release notes for the most recent release of the Electric Utility Network Configuration are described below.

February 2019

The February 2019 release of the Electric Utility Network v2.0.1 project package includes the following updates to the data model:

  • Removed subnetwork diagram templates from the Subnetworks layer.

August 2018

The August 2018 release of the Electric Network Editor v2.0 project package includes the following update to the data model:

  • Updated the Electric Network Editor maps to resolve an issue with group templates.

June 2018

The June 2018 release of the Electric Utility Network Configuration includes the following updates to the data model and maps:

General updates

  • First release of electric transmission domain
  • Configuration redesigned to accommodate a combined distribution and transmission networks
  • Added vertical coordinate system NADV88 (Height) ft
  • Removed all rules mapping to Unknown asset types
  • Conditional barrier added to Subnetwork Definitions where Network Category is equal to Network Category Ground
  • Conditional barrier added to Subnetwork Definitions where Lifecycle Network Attribute is not In Service and To Be Retired
  • Conflicting Association Roles have been resolved
  • Improvements made to rules
  • Attribute Rules defined to automatically calculate asset Ids on new feature. This is set to Disabled by default.

Map updates:

  • Removed default value for Phase Current in all feature templates in the Electric Network Editor map

Asset group and Asset type updates

Added:

  • Prefix of Electric added to all Structure asset groups
  • Structure Line / Aerial Support:
    • 124: Shield Wire
  • Structure Junction / Electric High Voltage Pole:
    • 321: H-Frame
    • 324: Single Pole
    • 330: Single Circuit Lattice
    • 331: Dual Circuit Lattice
    • 332: Triple Circuit Lattice
  • Structure Junction / Electric Medium Voltage Pole:
    • 321: H-Frame
    • 324: Single Pole
  • Structure Junction / Electric Low Voltage Pole:
    • 324: Single Pole
    • 325: Ornamental
  • Structure Junction / Bay:
    • 441: Cabinet Bay
    • 442: Substation Bay
  • Structure Boundary / Electric Switchgear Boundary:
    • 0: Unknown
    • 161: Distribution Pad Mounted
  • Structure Boundary / Electric Bay Boundary:
    • 0: Unknown
    • 201: Switchgear Bay
    • 202: Substation Bay
  • Structure Boundary / Electric Substation Boundary:
    • 84: Transmission Switching Substation
  • Structure Junction / Electric Switchgear:
    • 402: High Voltage Switchgear

Modified:

  • Structure Junction / Switchgear:
    • 401: Switchgear to 401: Medium Voltage Switchgear
  • Electric Distribution Device:
    • Capacitor to Power Factor Correcting Equipment
  • Structure Boundary:
    • Cabinet to Electric Cabinet Boundary
  • Structure Junction / Electric Cabinet Boundary:
    • 40: Cabinet to 40: Cabinet Boundary
  • Structure Boundary:
    • Storage Facility to Electric Storage Facility Boundary
  • Structure Boundary:
    • Vault to Vault Boundary
  • Structure Boundary / Vault Boundary:
    • 1: Vault to 1: Vault Boundary
  • Structure Boundary:
    • Substation to Electric Substation Boundary
  • Structure Boundary / Electric Substation Boundary:
    • 82: Distribution to 82: Distribution Substation
    • 83: Transmission to 83: Transmission Substation
  • Electric Line / Low Voltage:
    • 81: Overhead Single Phase to 161: Overhead Single Phase
    • 82: Overhead Three Phase to 162: Overhead Three Phase
    • 83: Overhead Two Phase to 163: Overhead Two Phase
    • 84: Underground Single Phase to 164: Underground Single Phase
    • 85: Underground Three Phase to 165: Underground Single Phase
    • 86: Underground Two Phase to 166: Underground Two Phase
  • Electric Device / Power Factor Correcting Equipment:
    • 82: Overhead Single Phase to 82:Overhead Single Phase Capacitor
    • 83: Overhead Three Phase to 83: Overhead Three Phase Capacitor
    • 84: Pad Mounted Single Phase to 84: Pad Mounted Single Phase Capacitor
    • 85: Pad Mounted Three Phase to 85: Pad Mounted Three Phase Capacitor

Removed:

  • Assignment of association roles on Unknown asset types
  • Structure Junction / Poles
  • Structure Junction / Switchgear:
    • Cabinet Bay
  • Structure Junction / Cabinet:
    • Cabinet Bay
  • Structure Boundary / Electric Substation Boundary:
    • 81: Bay

Field updates

Added:

  • All feature classes:
    • Field lifecyclestatus with alias of Lifecycle Status with a domain of Lifecycle_Combined at the field level and Lifecycle_Status at each asset group level
  • Structure Line and Electric Distribution Device:
    • Field ownedby with alias of Asset Owner with a domain of Asset_Owner for each asset group
    • Field maintby with alias of Asset Manager with a domain of Asset_Manager for each asset group
  • Electric Distribution Junction and Electric Distribution Device:
    • Field maxvoltage with alias of Maximum Operating Voltage with a domain of Electric_Distribution_Nominal_Voltage for each asset group
  • Electric Distribution Device:
    • powerrating
    • powermeasure
    • addpowerrating
    • designtype
  • Electric Distribution Device field powerrating alias set to kvar with a domain of Electric_Distribution_KVAR set for:
    • Power Factor Correcting Equipment
  • Electric Distribution Device field powerrating alias set to kVA with a domain of Electric_Distribution_KVA set for:
    • Voltage Regulator
    • Transformer
  • Electric Distribution Device field powerrating alias set to Service Load with a domain of Electric_Distribution_Service_Load set for:
    • Service Point
  • Electric Distribution field powerrating alias set to Generation Watts with a domain of DeviceElectric_Distribution_Generation_Watts set for:
    • Generation
  • Electric Distribution Device field powerrating alias set to Maximum Continuous Current with a domain of Electric_Distribution_Fuse_Continuous_Amps set for:
    • Fuse
  • Electric Distribution Device field powerrating alias set to Discharge Current with a domain of Electric_Distribution_Arrester_Discharge_Voltage set for:
    • Arrester
  • Electric Distribution Device field addpowerrating alias set to Maximum Interrupting Current with a domain of Electric_Distribution_Fuse_Interrupting_Amps set for:
    • Fuse
  • Electric Distribution Device field addpowerrating alias set to Low Side Voltage with a domain of Electric_Distribution_Nominal_Voltage set for:
    • Transformer
  • Electric Distribution Device field powermeasure alias set to Bulb Watts with a domain of Electric_Distribution_Light_Watts set for:
    • Street Light
  • Electric Distribution Device field maxvoltage alias set to Maximum Operating Voltage with a domain of Electric_Distribution_Nominal_Voltage set for:
    • Arrester
    • Circuit Breaker
    • Fuse
    • Network Protector
    • Switch
    • Generation
    • Line Monitor
    • Service Point
    • Streetlight
    • Transformer
    • Voltage Regulator
    • Power Factor Correcting Equipment
  • Electric Distribution Device field devicestatus alias set to Device Status with a domain of Electric_Device_Status set for:
    • Circuit Breaker
    • Fuse
    • Network Protector
    • Switch
  • Electric Distribution Device field devicestatus alias set to Device State with a domain of Electric_Device_State set for:
    • Arrester
    • Generation
    • Line Monitor
    • Service Point
    • Streetlight
    • Transformer
    • Voltage Regulator
    • Power Factor Correcting Equipment
  • Electric Distribution Device field designtype alias set to Gang Operated with a domain of Yes_No set for:
    • Circuit Breaker
    • Switch
    • Transformer
    • Voltage Regulator
  • Electric Distribution Device field designtype alias set to Light Type with a domain of Electric_Distribution_Device_Street_Light_Type set for:
    • Street Light
  • Structure Junction field designtype alias set to Anchor Type for:
    • Electric Guy
  • Structure Junction field designtype alias set to Class for:
    • Electric High Voltage Pole
    • Electric Medium Voltage Pole
    • Electric Low Voltage Pole
    • Electric Support Pole
  • Structure Junction field designtype alias set to Compartments for:
    • Electric Cabinet
    • Electric Manhole
    • Electric Platform
    • Electric Vault
    • Electric Switchgear
  • Structure Junction field depth alias set to Depth for:
    • Electric Handhole
    • Electric Manhole
    • Electric Junction Box
    • Electric High Voltage Pole
    • Electric Medium Voltage Pole
    • Electric Low Voltage Pole
    • Electric Support Pole
    • Electric Vault
  • Structure Junction field structureheight alias set to Structure Height for:
    • Electric High Voltage Pole
    • Electric Medium Voltage Pole
    • Electric Low Voltage Pole
    • Electric Support Pole
  • Structure Junction field quantitysize alias set to Anchor Size for:
    • Electric Guy
  • Structure Junction field quantitysize alias set to Duct Count for:
    • Electric Manhole
  • Structure Junction field dimension alias set to Diameter for:
    • Electric Manhole
  • Structure Junction field dimension alias set to Dimensions for:
    • Electric Cabinet
    • Electric Handhole
    • Electric Junction Box
    • Electric Pad
    • Electric Pedestal
    • Electric Platform
    • Electric Switchgear
  • Electric Distribution Assembly field configuration alias Configuration with a domain of Electric_Assembly_Configuration_Type set for:
    • Transformer Bank

Modified:

  • Depth from integer to double for Structure Junction
  • Default field removed from Electric Distribution Line:
    • nominal voltage
    • commonconductortype
  • Default value set to Null on all Subtypes and Fields for the following:
    • Electric Device / Phase Current
    • Electric Junction / Phase Current
    • Electric Line / Phase Current

Removed:

  • Removed fields from Structure Junction:
    • model
    • manufacturer
    • ductcount
    • guyanchorsize
    • guyanchortype
    • diameter
    • depth
    • compartments
    • dateinstalled
    • class
  • Removed fields from Structure Line:
    • model
    • material
    • manufacturer
  • Removed fields from Electric Distribution Device:
    • model
    • manufacturer
    • yearmanufactured
    • arreseter_dischargecurrent
    • fuse_continuous_amps
    • fuse_interrupting_amps
    • gangoperated_kvar
    • lowsidevoltage
    • regulator_kva
    • service_load
    • transformer_kva
    • generationkw
    • labeltext
    • serialnumber
  • Default field removed from Electric Distribution Line
  • Removed fields for Electric Distribution Junction:
    • labeltext
  • Removed fields for Electric Distribution Assembly:
    • notes
  • Removed fields from Electric Distribution Line:
    • notes

Attribute domain updates:

General:

  • All domains changed from Split policy to Duplicate
  • All attribute domains renamed to replace spaces with an underscore

Added:

  • Electric_Assembly_Configuration_Type:
    • 0: Unknown
    • 1: Delta / Delta
    • 2: Delta / Wye
    • 3: Wye / Delta
    • 4: Wye / Wye
  • Asset_Owner:
    • 1: Our Agency
    • 2: Private
    • 100: Other
  • Asset_Manager:
    • 1: Our Agency
    • 2: Private
    • 100: Other
  • Lifecycle_Status:
    • 0: Unknown
    • 1: Proposed
    • 2: Approved
    • 4: Under Construction
    • 8: In Service
    • 16: To Be Retired
    • 32: Abandoned
  • Lifecycle_Combined:
    • 0: Unknown
    • 1: Proposed
    • 2: Approved
    • 3: Proposed and Approved
    • 4: Under Construction
    • 6: Approved and Under Construction
    • 7: Proposed, Approved, and Under Construction
    • 8: In Service
    • 12: In Service and Under Construction
    • 14: In Service, Under Construction, and Approved
    • 15: In Service, Under Construction, Approved and Proposed
    • 16: To Be Retired
    • 24: In Service and To Be Retired
    • 32: Abandoned
  • Electric_Device_State:
    • 3: Active
    • 4: Inactive

Modified:

  • UN_SymbolRotation to Symbol_Rotation
  • UN_Yes_No renamed to Yes_No
  • Electric_Distribution_Medium_Voltage_Conductor_Material:
    • 1: Single Conductor to 501: Single Conductor
    • 2: Duplex to 502: Duplex
    • 3: Triplex to 503 Triplex
    • 4: Quadraplex to 504: Quadraplex
  • Electric_Distribution_Medium_Voltage_Busbar_Material:
    • 1: Solid Aluminium to 401: Solid Aluminium
    • 2: Solid Copper to 402: Solid Copper
    • 3: Solid Steel to 403: Solid Steel
  • Electric_Distribution_Device_Capacitor to Electric_Distribution_Device_Power_Factor_Correcting_Equipment
  • Life_Cycle_Status to Lifecycle_Status

Removed:

  • Attribute domain removed from Electric Device / Gang Operated
  • Nominal Voltage removed from ElectricDistributionLine: Neutral nominal voltage field
  • Electric Distribution Nominal Voltage attribute domain removed from ElectricDistributionLine nominalvoltage field
  • Electric Distribution Neutral Material attribute domain removed from ElectricDistributionLine commonconductortype field

Network attribute updates

General:

  • Network Attribute assignment updated to capture new attribute domain names

Added:

  • Lifecycle Status
  • Power Rating

Modified:

  • Is_nullable changed from True to False for the following:
    • Device Asset Group
    • Device Status
    • Line Asset Group
    • Phase Current
  • Phases Current network to Distribution Phases Current
  • NominalVoltage to Nominal Voltage
  • Operational Device Status to Electric Device Status

Removed:

  • Service Load
  • Generation KW

Terminal configuration updates

Added:

  • Four Terminal Bypass Switch with the following terminals:
    • Bypass:Regulator Source
    • Bypass:Regulator Load
    • Bypass:Regulator In Bushing
    • Bypass:Regulator Out Bushing
  • Overhead Voltage Regulator with the following terminals:
    • VR:In Bushing
    • VR:Out Bushing
  • Inverter with the following terminals:
    • INV:DC Input
    • INV:AC Output
  • Rectifier with the following terminals:
    • RT:DC Output
    • RT:AC Input
  • High Voltage Disconnect Switch with the following terminals:
    • HVDS:Bus Side
    • HVDS:Line Side
  • High Voltage Inline Switch with the following terminals:
    • HVIS:Terminal A
    • HVIS:Terminal B
  • Circuit Breaker with the following terminals:
    • CB:Bus Side
    • CB:Line Side

Modified:

  • Dual Terminal:
    • Terminals Source to DT:Source
    • Terminals Load to DT:Load
  • Transformer:
    • Terminals High to XFR:High
    • Terminals Low to XFR:Low

Removed:

  • Bypass Switch

Categories

Added:

  • Ground

Known issues

Known limitations of the Electric Utility Network Configuration are listed below. Software developers are working to fix these issues in a future release of the configuration.

  • If you deploy Electric Distribution and Electric Transmission in the same network, the circuit group layers in the SubnetLine class will have an incorrect definition expression. The expressions will have to be adjusted to the appropriate tier subtype codes as follows:
    • Electric Distribution tiers:
      • Medium Voltage—Subtype code 1
      • Low Voltage—Subtype code 2
    • Electric Transmission tiers:
      • AC Voltage—Subtype code 3
      • DC Voltage—Subtype code 4
  • The ArcGIS Solutions Deployment Tool does not support deploying maps and apps using the utility network simple map service. Solutions deployed will use the utility network feature service that has been published to your organization.
Top