Introduction
The data dictionary includes a description of the elements in the Water Distribution Utility Network Foundation.
It will help you understand what elements are used to create the utility network and provide a description of
what they are.
Feature Classes
ServiceTerritory
The networks service territory that represents the operational area of the utility.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Service Territory | False |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | OBJECTID | OID | False | |||
name | Utility Name | TEXT (50) | True | |||
globalid | GLOBALID | GUID | False | |||
creator | Creator | TEXT (255) | True | |||
creationdate | CreationDate | DATE | True | |||
updatedby | UpdatedBy | TEXT (255) | True | |||
lastupdate | LastUpdate | DATE | True | |||
shape | shape | GEOMETRY | True | |||
shape_length | shape_Length | DOUBLE | True | |||
shape_area | shape_Area | DOUBLE | True |
Inspection Tables
HydrantMaintenanceInspection
The Hydrant Maintenance Inspection table is related through a relationship class to the Water Device feature class are stores maintenance inspection records for hydrants.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
TABLE | Hydrant Maintenance Inspection | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | OBJECTID | OID | False | |||
pressure | Pressure (PSI) | DOUBLE | True | |||
inspector | Inspector | TEXT (50) | True | |||
chains | Chains Req'd? | SHORT | Yes_No | True | ||
paint | Paint Req'd? | SHORT | Yes_No | True | ||
marker | Marker Req'd? | SHORT | Yes_No | True | ||
oil | Lubrication Req'd? | SHORT | Yes_No | True | ||
stamped | Stamped? | SHORT | Yes_No | True | ||
greased | Greased? | SHORT | Yes_No | True | ||
drain | Drain? | SHORT | Yes_No | True | ||
notes | Notes | TEXT (2000) | True | |||
hydrantid | Hydrant ID | GUID | True | |||
globalid | GlobalID | GUID | False | |||
insdate | Inspection Date | DATE | True | |||
creator | creator | TEXT (255) | True | |||
creationdate | creationdate | DATE | True | |||
updatedby | updatedby | TEXT (255) | True | |||
lastupdate | lastupdate | DATE | True | |||
flowduration | Flow Duration | DOUBLE | True | |||
flowrate | Flow Rate | DOUBLE | True |
ValveInspection
The Valve Inspection table is related through a relationship class to the Water Device feature class are stores inspection records for valves.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
TABLE | Valve Inspection | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | OBJECTID | OID | False | |||
paved | Paved Over | SHORT | 0.0 | Yes_No_Not_Applicable | True | |
gsurface | Ground Surface | SHORT | Water_Valve_Surface_Type | True | ||
fintorque | Final Torque (Ft Pounds) | DOUBLE | True | |||
depthtonut | Depth To Nut (Ft) | DOUBLE | True | |||
turns | # of Turns | DOUBLE | True | |||
operator | Name of Operator | TEXT (100) | True | |||
stem | Stem OK? | SHORT | Yes_No | True | ||
package | Packing OK? | SHORT | Yes_No | True | ||
gears | Gears OK? | SHORT | Yes_No | True | ||
lube | Lube Req'd? | SHORT | Yes_No | True | ||
other | Other Maint Req'd? | SHORT | Yes_No | True | ||
notes | Notes | TEXT (2000) | True | |||
valveid | Valve ID | GUID | True | |||
globalid | GlobalID | GUID | False | |||
creator | Creator | TEXT (255) | True | |||
creationdate | CreationDate | DATE | True | |||
updatedby | UpdatedBy | TEXT (255) | True | |||
lastupdate | LastUpdate | DATE | True | |||
insdate | Inspection Date | DATE | True |
Utility Network Domain Feature Classes
WaterAssembly
The Assembly feature class represents complex point features which contain other devices and lines. Like device features, assembly features are compact features but they differ in that assemblies contain other significant devices. Assemblies are useful to show a single symbol on the map yet model the internal features and their connections. Assemblies can contain devices, lines, and junctions. You can view the internal features of an assembly on the map or in the diagram view.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Water Assembly | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | 0 | False | ||
assettype | Asset type | SHORT | 0 | False | ||
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | cpsubnetworkname: CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | systemsubnetworkname: System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | pressuresubnetworkname: Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | isolationsubnetworkname: Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | dmasubnetworkname: DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | installdate: Install Date | DATE | True | |||
assetid | assetid: Asset ID | TEXT (64) | True | |||
notes | notes: Notes | TEXT (2000) | True | |||
locked | locked: Locked | SHORT | True | |||
symbolrotation | symbolrotation: Symbol Rotation | SHORT | 0 | Symbol_Rotation | True | |
lifecyclestatus | lifecyclestatus: Lifecycle Status | SHORT | 0 | Lifecycle_Combined | False | |
inservicedate | inservicedate: In-Service Date | DATE | True | |||
retireddate | retireddate: Retired Date | DATE | True | |||
spatialsource | spatialsource: Spatial Source | SHORT | Spatial_Source | True | ||
spatialconfidence | spatialconfidence: Spatial Confidence | SHORT | Spatial_Confidence | True |
Subtypes
Code | Name | Description |
---|---|---|
0 | Unknown | The Unknown asset group in the WaterAssembly feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. |
3 | Backflow | The Backflow asset group in the WaterAssembly feature class represents collections of devices, junctions and lines that prevent back flow. |
5 | Blow Off | The Blow Off asset group in the WaterAssembly feature class represent a point feature which can contain a blow off device or a collection of asset that are used to flush water from the system. |
6 | Meter Station | The Meter Station asset group in the WaterAssembly feature class represents a point feature that contain a collection of meters, valve and pipes typically used in multi-unit dwellings. |
7 | Horizontal Valve | The Horizontal Valve asset group in the WaterAssembly feature class represents a point feature for large valves where the drive nut and bypass nut are offset from the valve. |
8 | Pressure Reducing Station | The Pressure Reducing Station asset group in the WaterAssembly feature class represents a point feature that contains the asset to reduce pressure in the system. |
10 | Hydrant | The Hydrant asset group in the Assembly feature class represents a point feature that contains the hydrants, service line and valve for cartographic purposes. |
9 | Air Vacuum and Air Release | The Air Vacuum & Air Release asset group in the Assembly feature class represents a point feature that contains assets to release pressure in the system. |
Subtype: Unknown
The Unknown asset group in the WaterAssembly feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Water_6_UnknownAssetType | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
locked | Locked | SHORT | True | |||
symbolrotation | Symbol Rotation | SHORT | True | |||
lifecyclestatus | Lifecycle Status | SHORT | False | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | True | |||
spatialconfidence | Spatial Confidence | SHORT | True |
Subtype: Unknown: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | The Unknown asset group in the WaterAssembly feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Backflow
The Backflow asset group in the WaterAssembly feature class represents collections of devices, junctions and lines that prevent back flow.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Assembly_Backflow | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
locked | Locked | SHORT | 0 | Yes_No | True | |
symbolrotation | Symbol Rotation | SHORT | 0 | Symbol_Rotation | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Backflow: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of backflow assembly. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
1 | Double Check Detector | Backflow device with two check valves in series with a meter. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
2 | Double Check Valve | Backflow device with two check valves in series. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
3 | Reduced Pressure Detector | Backflow device with two check valves in series and a hydraulically operated differential release valve with a meter. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
4 | Reduced Pressure Zone | Backflow device with two check valves in series and a hydraulically operated differential release valve. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Blow Off
The Blow Off asset group in the WaterAssembly feature class represent a point feature which can contain a blow off device or a collection of asset that are used to flush water from the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Assembly_Blow_Off | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
locked | Locked | SHORT | True | |||
symbolrotation | Symbol Rotation | SHORT | 0 | Symbol_Rotation | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Blow Off: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of blow off. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
41 | Automatic | Automatic blow off. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
42 | Manual | Manually controlled blow off. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Meter Station
The Meter Station asset group in the WaterAssembly feature class represents a point feature that contain a collection of meters, valve and pipes typically used in multi-unit dwellings.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Assembly_Meter_Station | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | 0 | Symbol_Rotation | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Meter Station: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of meter station. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
81 | Meter Station | Location and container for a collection of meters for sub-metering. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Horizontal Valve
The Horizontal Valve asset group in the WaterAssembly feature class represents a point feature for large valves where the drive nut and bypass nut are offset from the valve.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Assembly_Horizontal_Valve | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | 0 | Symbol_Rotation | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Horizontal Valve: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of horizontal valve. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
121 | Operator Nut | Large diameter valve that contains the system valve and operaor nut. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
122 | Operator Nut and Bypass Valve | Large diameter valve that contains the system valve, operaor nut and bypass valve. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Pressure Reducing Station
The Pressure Reducing Station asset group in the WaterAssembly feature class represents a point feature that contains the asset to reduce pressure in the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Assembly_Pressure_Reducing_Station | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | 0 | Symbol_Rotation | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Pressure Reducing Station: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of pressure reducing station. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
161 | Pressure Reducing Station | Location and container for a pressure reducing station. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Hydrant
The Hydrant asset group in the Assembly feature class represents a point feature that contains the hydrants, service line and valve for cartographic purposes.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Assembly_Hydrant | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Hydrant: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of hydrant assembly. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
241 | Fire Hydrant | Standard hydrant configuration. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Air Vacuum and Air Release
The Air Vacuum & Air Release asset group in the Assembly feature class represents a point feature that contains assets to release pressure in the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Assembly_Air_Vacuum_and_Air_Release | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | 0 | Symbol_Rotation | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Air Vacuum and Air Release: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of air vacuum & air release assembly. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
201 | Air Vacuum and Air Release | Location and container for a Air Vacuum & Air release station. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
WaterDevice
These Device feature class represents features through which your utility resource flows and devices can affect your resource in several ways. Devices can optionally have terminals when there are distinct entry points to the device. Devices can be connected to other devices, junctions, and lines. Devices can be contained within assemblies.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Water Device | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | 0 | False | ||
assettype | Asset type | SHORT | 0 | False | ||
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | tiername: Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | terminalconfiguration: Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | cpsubnetworkname: CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | systemsubnetworkname: System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | pressuresubnetworkname: Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | isolationsubnetworkname: Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | dmasubnetworkname: DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | diameter: Diameter, Diameter 1, Height, Inlet Diameter, Pipe Diameter, Weight | DOUBLE | True | |||
secondarydiameter | secondarydiameter: Diameter 2, Nozzle Diameter, Outlet Diameter, Width | DOUBLE | True | |||
pressure | pressure: Amperage, Pressure, Rated Pressure, Volume | DOUBLE | True | |||
designtype | designtype: Design Type, Manufacturer, Pump Type, Test Wire Count, Valve Type, Wire Count | SHORT | True | |||
normalstatus | normalstatus: Normal Status | SHORT | Pipeline_Device_Status_Combined | False | ||
presentstatus | presentstatus: Present Status | SHORT | Pipeline_Device_Status_Combined | False | ||
additionaldetails | additionaldetails: Clockwise to Close, Cooling Method, Critical, Material | SHORT | True | |||
designinfo | designinfo: Rated Flow, Turns to Close, Voltage | DOUBLE | True | |||
operable | operable: Operable | SHORT | 1 | Boolean | False | |
name | name: Name | TEXT (64) | True | |||
installdate | installdate: Install Date | DATE | True | |||
assetid | assetid: Asset ID | TEXT (64) | True | |||
accountid | accountid: Account ID | TEXT (50) | True | |||
ownedby | ownedby: Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | maintby: Maintained By | SHORT | 1 | Asset_Manager | True | |
additionaldevice | additionaldevice: Additional Device, Has Bypass, Internal Meter, Metered | SHORT | True | |||
notes | notes: Notes | TEXT (2000) | True | |||
symbolrotation | symbolrotation: Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | lastmaint: Last Maintenance | DATE | True | |||
lifecyclestatus | lifecyclestatus: Lifecycle Status | SHORT | 0 | Lifecycle_Combined | False | |
bondedinsulated | bondedinsulated: Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | cptraceability: Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | inservicedate: In-Service Date | DATE | True | |||
retireddate | retireddate: Retired Date | DATE | True | |||
spatialsource | spatialsource: Spatial Source | SHORT | Spatial_Source | True | ||
spatialconfidence | spatialconfidence: Spatial Confidence | SHORT | Spatial_Confidence | True | ||
cpoverride | cpoverride: Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtypes
Code | Name | Description |
---|---|---|
0 | Unknown | The Unknown asset group in the WaterDevice feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. |
1 | Flow Valve | The Flow Valve asset group in the WaterDevice feature class represents valves that control the direction of flow in the system. |
10 | Meter | The Meter asset group in the WaterDevice feature class represents water meters. |
17 | Filter | The Filter asset group in the WaterDevice feature class represents filters used in water assemblies. |
18 | Controller | The Controller asset group in the WaterDevice feature class represents components that control a valve as a separate feature from the valve. These are used in large valve assemblies where the drive nut of bypass is located at an offset from the valve. |
2 | Controllable Valve | The Controllable Valve asset group in the WaterDevice feature class represents valves with a primary purpose of enabling or restricting the flow of water. |
4 | Station | The Station asset group in the WaterDevice feature class represents facilities that are used for collecting water samples. |
5 | Pump | The Pump asset group in the WaterDevice feature class represents facilities that move, compress, or alters the pressure of a fluid. |
7 | Fire Hydrant | The Fire Hydrant asset group in the WaterDevice feature class represents fire hydrants. |
9 | Flushing and Blow Off | The Flushing and Blow Off asset group in the WaterDevice feature class represents facilities with a primary purpose of flushing water from the system. |
19 | Injection Facility | The Injection Facility asset group in the WaterDevice feature class represents devices that inject chemicals into a water network. |
50 | Anode | The Anode asset group in the WaterDevice feature class represents features applied to water system components to prevent rust, pitting or corrosion. |
51 | Rectifier | The Rectifier asset group in the WaterDevice feature class represents devices that convert alternating current to direct current for a cathodic protection system. |
52 | Test Point | The Test Point asset group in the WaterDevice feature class represents the read point location where electric potential can be measured for a cathodic protection system. |
20 | Storage | The Storage asset group in the WaterDevice feature class represents assets with a primary function of water storage as a point. |
15 | Supply | The Supply asset group in the WaterDevice feature class represents assets with a primary function of supplying water to the system. |
8 | Outlet | The Outlet asset group in the WaterDevice feature class represents assets with the primary function of draining water from the system. |
3 | Pressure Valve | The Pressure Valve asset group in the WaterDevice feature class represents valves with a primary function managing pressure in the system. |
11 | Monitoring | The Monitoring asset group in the WaterDevice feature group represents assets other than meters that monitor a water in the system. |
12 | Service Connection | The Service Connection asset group in the WaterDevice feature group represents the connections for service in the water system. |
Subtype: Unknown
The Unknown asset group in the WaterDevice feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Water_6_UnknownAssetType | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Diameter, Diameter 1, Height, Inlet Diameter, Pipe Diameter, Weight | DOUBLE | True | |||
secondarydiameter | Diameter 2, Nozzle Diameter, Outlet Diameter, Width | DOUBLE | True | |||
pressure | Pressure, Amperage | DOUBLE | True | |||
designtype | Design Type, Manufacturer, Pump Type, Valve Type, Manufacturer, Wire Count | SHORT | True | |||
normalstatus | Normal Status | SHORT | 1 | Pipeline_Valve_Status | False | |
presentstatus | Present Status | SHORT | 1 | Pipeline_Valve_Status | False | |
additionaldetails | Clockwise to Close, Material, Cooling Method | SHORT | True | |||
designinfo | Turns to Close, Voltage | DOUBLE | True | |||
operable | Operable | SHORT | 1 | Boolean | False | |
name | Name | TEXT (64) | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
accountid | Account ID | TEXT (50) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
additionaldevice | Has Bypass, Internal Meter | SHORT | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | False | |||
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | True | |||
spatialconfidence | Spatial Confidence | SHORT | True | |||
cpoverride | Cathodic Protection Override | SHORT | True |
Subtype: Unknown: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | The Unknown asset group in the WaterDevice feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Flow Valve
The Flow Valve asset group in the WaterDevice feature class represents valves that control the direction of flow in the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Flow_Valve | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Diameter | DOUBLE | 0 | Water_Diameter | True | |
pressure | Pressure | DOUBLE | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Flow Valve: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of flow valve. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
1 | Air Gap | Unobstructed vertical space to prevent backflow. | Pipe Bidirectional Dual Terminal | ['Protective'] | NONE | DO_NOT_SPLIT | END_VERTEX |
2 | Altitude | Valve that controls water flow into a tower when the water level drops below a threshold. | Pipe Bidirectional Dual Terminal | ['Protective'] | NONE | DO_NOT_SPLIT | END_VERTEX |
3 | Check | Valve that closes to prevent backward flow of water. | Pipe Directional Dual Terminal | ['Protective'] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Meter
The Meter asset group in the WaterDevice feature class represents water meters.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Meter | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Diameter | DOUBLE | 0 | Water_Meter_Diameter | True | |
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
accountid | Account ID | TEXT (50) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Meter: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of water meter. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
41 | Bulk | Meter for measuring bulk water use. | Pipe Bidirectional Dual Terminal | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
42 | Commercial | Meter for measuring water use at a commercial premise. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
43 | DMA | Meter for measuring water flowing in our out of a district metered area. | Pipe Bidirectional Dual Terminal | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
44 | Emergency Connection | Meter for measuring water use at an emergency connection. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
45 | Industrial | Meter for measuring water use at an industrial premise. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
46 | Master | Master meter for measuring water at a premise with submetering. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
47 | Pump Station | Meter for measuring water at a pump station. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
48 | Residential | Meter for measuring water at a residential premise. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Filter
The Filter asset group in the WaterDevice feature class represents filters used in water assemblies.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Filter | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Filter: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of filter. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
81 | Strainer | Device used to capture foreign debris to prevent fouling of check valve. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Controller
The Controller asset group in the WaterDevice feature class represents components that control a valve as a separate feature from the valve. These are used in large valve assemblies where the drive nut of bypass is located at an offset from the valve.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Controller | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Controller: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of controller. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
121 | Bypass Valve | Location of bypass nut used in large diameter controllable valves. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
122 | Operator Nut | Location of operator nut used in large diameter controllable valves. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Controllable Valve
The Controllable Valve asset group in the WaterDevice feature class represents valves with a primary purpose of enabling or restricting the flow of water.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Controllable_Valve | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Diameter | DOUBLE | 0 | Water_Diameter | True | |
designtype | Valve Type | SHORT | Water_Valve_Type | True | ||
normalstatus | Normal Status | SHORT | 1 | Pipeline_Valve_Status | False | |
presentstatus | Present Status | SHORT | 1 | Pipeline_Valve_Status | False | |
additionaldetails | Clockwise to Close | SHORT | 1 | Pipeline_Valve_Close_Direction | True | |
designinfo | Turns to Close | DOUBLE | True | |||
operable | Operable | SHORT | Boolean | False | ||
name | Name | TEXT (64) | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
additionaldevice | Has Bypass | SHORT | 0 | Yes_No | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Controllable Valve: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of controllable valve. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
161 | Blow Off | Valve used in conjunction with an outlet in a blow off assembly. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
164 | Hydrant | Valve for fire hydrant. | Single terminal | ['Disconnecting'] | NONE | DO_NOT_SPLIT | END_VERTEX |
167 | Isolation Zone | System Valve used as the controller of isolation zones. | Pipe Bidirectional Dual Terminal | ['Isolating', 'Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
169 | Supply | Valve for a supply line. | Single terminal | ['Isolating'] | NONE | DO_NOT_SPLIT | END_VERTEX |
170 | System | Valve with a primary purpose of isolation areas of the water network. | Single terminal | ['Isolating'] | NONE | DO_NOT_SPLIT | END_VERTEX |
171 | Sampling | Valve for a sampling service. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
172 | Pressure Zone | Valve with a primary purpose of separating different pressure zones in a water system. | Single terminal | ['Isolating'] | NONE | DO_NOT_SPLIT | END_VERTEX |
173 | Bypass | Valve for a bypass line. | Single terminal | ['Isolating'] | NONE | DO_NOT_SPLIT | END_VERTEX |
174 | Purge | Valve used as part of an assembly to purge air or water. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
175 | Interconnect | Valve with a primary purpose of interconnecting different water systems. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
176 | Service | Valve for a service connection. | Single terminal | ['Disconnecting'] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Station
The Station asset group in the WaterDevice feature class represents facilities that are used for collecting water samples.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Station | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Station: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of sample station. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
241 | Sample Station | Station used to obtain samples of water for testing. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Pump
The Pump asset group in the WaterDevice feature class represents facilities that move, compress, or alters the pressure of a fluid.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Pump | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Inlet Diameter | DOUBLE | 0 | Water_Pump_Diameter | True | |
secondarydiameter | Outlet Diameter | DOUBLE | 0 | Water_Pump_Diameter | True | |
pressure | Rated Pressure | DOUBLE | True | |||
designtype | Pump Type | SHORT | 0 | Water_Pump_Type | True | |
normalstatus | Normal Status | SHORT | 3 | Pipeline_Device_Status | False | |
presentstatus | Present Status | SHORT | 3 | Pipeline_Device_Status | False | |
designinfo | Rated Flow | DOUBLE | True | |||
operable | Operable | SHORT | 1 | Boolean | False | |
name | Name | TEXT (64) | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Pump: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of pump. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
281 | Booster | Pump that only boosts pressure. | Pressure Increasing | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
282 | Chemical | Pump that feeds chemicals. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
283 | Primary | Pump that moves water. | Pressure Increasing | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Fire Hydrant
The Fire Hydrant asset group in the WaterDevice feature class represents fire hydrants.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Fire_Hydrant | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Diameter | DOUBLE | 0 | Water_Hydrant_Service_Diameter | True | |
secondarydiameter | Nozzle Diameter | DOUBLE | 0 | Water_Hydrant_Nozzle_Diameter | True | |
designtype | Manufacturer | SHORT | 0 | Water_Fire_Hydrant_Manufacturer | True | |
presentstatus | Present Status | SHORT | 3 | Pipeline_Device_Status | False | |
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Fire Hydrant: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of fire hydrant. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
321 | Fire Hydrant | Point representing a fire hydrant. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Flushing and Blow Off
The Flushing and Blow Off asset group in the WaterDevice feature class represents facilities with a primary purpose of flushing water from the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Flushing_and_Blow_Off | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
name | Name | TEXT (64) | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Flushing and Blow Off: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of flushing device. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
361 | Automatic Flushing | Flushing device that is automatically triggered. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
362 | Fire Plug Valve | Fire plug valve with a primary purpose of flushing water from the system. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
363 | Hydrant | Hydrant with a primary purpose of flushing water from the system. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
364 | Post Hydrant | Hydrant with a primary purpose of flushing water from the system in a post configuration. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
365 | Blow Off | Non-hydrant device with a primary purpose of flushing water from the system. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Injection Facility
The Injection Facility asset group in the WaterDevice feature class represents devices that inject chemicals into a water network.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Injection_Facility | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
normalstatus | Normal Status | SHORT | 3 | Pipeline_Device_Status | False | |
presentstatus | Present Status | SHORT | 3 | Pipeline_Device_Status | False | |
name | Name | TEXT (64) | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Injection Facility: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of injection facility. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
401 | Chlorination | Chlorine injection device. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
402 | Fluoridation | Fluoride injection device. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Anode
The Anode asset group in the WaterDevice feature class represents features applied to water system components to prevent rust, pitting or corrosion.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Anode | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Weight | DOUBLE | 0 | CP_Anode_Weight | True | |
additionaldetails | Material | SHORT | 0 | CP_Anode_Material | True | |
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
cptraceability | Cathodic Protection Traceability | SHORT | 1 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Anode: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of anode. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
901 | ICCP | Point representing a impressed current cathodic protection anode. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
902 | Galvanic | Point representing a galvanic anode. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Rectifier
The Rectifier asset group in the WaterDevice feature class represents devices that convert alternating current to direct current for a cathodic protection system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Rectifier | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
designtype | Manufacturer | SHORT | 0 | CP_Rectifier_Manufacturer | True | |
additionaldetails | Cooling Method | SHORT | 0 | CP_Rectifier_Cooling_Method | True | |
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
additionaldevice | Additional Device | SHORT | 0 | Yes_No | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
cptraceability | Cathodic Protection Traceability | SHORT | 1 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Rectifier: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | An unknown type of rectifier. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
941 | Rectifier | Point representing a rectifier. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Test Point
The Test Point asset group in the WaterDevice feature class represents the read point location where electric potential can be measured for a cathodic protection system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Test_Point | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
designtype | Test Wire Count | SHORT | CP_Test_Point_Wire_Count | True | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
cptraceability | Cathodic Protection Traceability | SHORT | 1 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Test Point: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Test point for an unknown type of rectifier. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
981 | Test Point | Represesents the location of a rectifer. | Terminal Block | ['CP Only', 'Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Storage
The Storage asset group in the WaterDevice feature class represents assets with a primary function of water storage as a point.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Storage | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Height | DOUBLE | True | |||
secondarydiameter | Width | DOUBLE | True | |||
pressure | Volume | DOUBLE | True | |||
normalstatus | Normal Status | SHORT | 3 | Pipeline_Device_Status | False | |
presentstatus | Present Status | SHORT | 3 | Pipeline_Device_Status | False | |
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Storage: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of storage. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
561 | Reservoir | Point representing the location of a reservoir. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
562 | Standpipe | Standpipe water tower. | Pipe Bidirectional Dual Terminal | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
563 | Storage Tank | Storage tank at ground level. | Pipe Bidirectional Dual Terminal | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
564 | Tower | Elevated structure with a storage tank. | Pipe Bidirectional Dual Terminal | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
565 | Surge Tank | Point representing the location of a surge tank. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
566 | Hydropneumatic Tank | Point representing the location of a hydropneumatic tank. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Supply
The Supply asset group in the WaterDevice feature class represents assets with a primary function of supplying water to the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Supply | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
name | Name | TEXT (64) | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Supply: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of supply. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
601 | Treatment Plant | Water treatment plant. | Pipe Bidirectional Dual Terminal | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
602 | Well | Location of production well. | Pipe Bidirectional Dual Terminal | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
603 | Interconnect | Point representing an interconnection with anouther water service provider. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Outlet
The Outlet asset group in the WaterDevice feature class represents assets with the primary function of draining water from the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Outlet | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
name | Name | TEXT (64) | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Outlet: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of outlet. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
641 | Outlet | Generic Outlet used with a valve as part of a blow off assembly. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
642 | Yard Hydrant | Yard hydrant. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Pressure Valve
The Pressure Valve asset group in the WaterDevice feature class represents valves with a primary function managing pressure in the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Pressure_Valve | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Diameter | DOUBLE | 0 | Water_Diameter | True | |
pressure | Pressure | DOUBLE | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Pressure Valve: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of pressure valve. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
201 | Air and Vacuum | Valve with the primary purpose of allowing large volumes of air to be exhausted from or admitted into a water pipe as it is filled or drained. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
202 | Air Release | Valve with a primary role of releasing air pockets. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
203 | Combination Air | Valve with combined features of an air/vacuum valve and air release valve. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
204 | Pressure Limiting | Valve with a primary purpose of limiting the pressure of water traveling through the valve. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
205 | Pressure Reducing | Valve with a primary purpose of reducing the pressure of water exiting the valve. | Pressure Reducing | ['Subnetwork Controller'] | NONE | DO_NOT_SPLIT | END_VERTEX |
206 | Pressure Release | Valve with a primary role of relieving pressure to control or limit network pressure. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
207 | Pressure Sustaining | Valve with a primary purpose of maintaining a minimum upstream pressure. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Monitoring
The Monitoring asset group in the WaterDevice feature group represents assets other than meters that monitor a water in the system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Monitoring | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
issubnetworkcontroller | Is subnetwork controller | SHORT | 0 | Water_6_IsSubnetworkController | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
subnetworkcontrollername | Subnetwork controller name | TEXT (2000) | Unknown | False | ||
tiername | Tier name | LONG | 0 | Water_6_TierName | False | |
tierrank | Tier rank | LONG | 0 | False | ||
terminalconfiguration | Terminal path | TEXT (128) | Default | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
name | Name | TEXT (64) | True | |||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Monitoring: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of monitoring device. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
21 | Observation Well | Well for observing changes in groundwater levels. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
22 | Pressure Sensor | Sensor for observing water pressure . | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
23 | Temperature Sensor | Sensor for observing water temperature. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
24 | Detection Meter | Meter for backflow detection and leaks. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Service Connection
The Service Connection asset group in the WaterDevice feature group represents the connections for service in the water system.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset Group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Device_Service_Connection | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
shape | Shape | GEOMETRY | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
diameter | Diameter | DOUBLE | True | |||
additionaldetails | Critical | SHORT | 2 | Yes_No | True | |
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
accountid | Account ID | TEXT (50) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
additionaldevice | Metered | SHORT | 2 | Yes_No | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lastmaint | Last Maintenance | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Service Connection: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown service connection. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
61 | Commercial | Service connection for a commercial service. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
62 | Fire | Service connection for a fire service. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
63 | Industrial | Service connection for a industrial service. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
64 | Irrigation | Service connection for a irrigation service. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
65 | Residential | Service connection for a residential service. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
WaterJunction
The Junction class represents locations where lines connect to lines or lines connect to devices. A key use for junction features is to allow devices or lines to connect to another line at an intermediate vertex. You can think of a junction as 'glue point' at key places to connect all the features of a utility network. Junctions can be contained within assemblies.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Water Junction | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | 0 | False | ||
assettype | Asset type | SHORT | 0 | False | ||
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | cpsubnetworkname: CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | systemsubnetworkname: System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | pressuresubnetworkname: Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | isolationsubnetworkname: Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | dmasubnetworkname: DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | installdate: Install Date | DATE | True | |||
assetid | assetid: Asset ID | TEXT (64) | True | |||
notes | notes: Notes | TEXT (2000) | True | |||
symbolrotation | symbolrotation: Symbol Rotation | SHORT | Symbol_Rotation | True | ||
diameter | diameter: Diameter | DOUBLE | True | |||
lifecyclestatus | lifecyclestatus: Lifecycle Status | SHORT | 0 | Lifecycle_Combined | False | |
bondedinsulated | bondedinsulated: Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | cptraceability: Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | inservicedate: In-Service Date | DATE | True | |||
retireddate | retireddate: Retired Date | DATE | True | |||
spatialsource | spatialsource: Spatial Source | SHORT | Spatial_Source | True | ||
spatialconfidence | spatialconfidence: Spatial Confidence | SHORT | Spatial_Confidence | True | ||
ownedby | ownedby: Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | maintby: Maintained By | SHORT | 1 | Asset_Manager | True | |
cpoverride | cpoverride: Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtypes
Code | Name | Description |
---|---|---|
0 | Unknown | The Unknown asset group in the WaterJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. |
20 | Fitting | The Water Fitting asset group in the WaterJunction feature class represents junctions where pipes connect to pipes or devices. |
50 | Wire Junction | The Wire Junction asset group in the WaterJunction feature class represents cathodic protection junction features that connect to pipes. |
51 | Insulation Junction | The Insulation Junction asset group in the Water Junction feature class represents cathodic protection junction features where the electric current stops. |
Subtype: Unknown
The Unknown asset group in the WaterJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Water_6_UnknownAssetType | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
diameter | Diameter | DOUBLE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | False | |||
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | True | |||
spatialconfidence | Spatial Confidence | SHORT | True | |||
ownedby | Owned By | SHORT | True | |||
maintby | Maintained By | SHORT | True | |||
cpoverride | Cathodic Protection Override | SHORT | True |
Subtype: Unknown: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | The Unknown asset group in the WaterJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Fitting
The Water Fitting asset group in the WaterJunction feature class represents junctions where pipes connect to pipes or devices.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Junction_Fitting | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
diameter | Diameter | DOUBLE | 0 | Water_Fitting_Diameter | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Fitting: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of fitting. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
41 | Corporation Stop | Fitting connecting a main to a service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
42 | Coupling | Fitting with a socket at both ends connecting 2 pipes of the same size that is joined, welded, brazed or soldered. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
43 | Cross | Fitting connecting 4 pipes of the same size. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
44 | Elbow | Fitting connecting 2 pipes to allow a change in direction. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
45 | End Cap | Fitting to cover an open end of a pipe. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
46 | Expansion Joint | Fitting connecting 2 pipes designed to absorb thermal expansion or movement. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
47 | Flange | Fitting connecting pipes or valves with threaded bolts, wedges, clamps or other means of high compressive force. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
48 | Plug | Fitting inserted inside a pipe segment to stop flow. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
49 | Reducer | Fitting connecting 2 pipes of different sizes. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
50 | Reducing Cross | Fitting connecting 4 pipes of different sizes. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
51 | Reducing Tee | Fitting connecting 3 pipes of different sizes. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
52 | Saddle | Fitting connecting 2 pipes by placing 2 different sides of the fitting around the pipes and securing in place with bolts. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
53 | Screw | Fitting connection 2 pipes by screwing the pipes together. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
54 | Sleeve | Fitting connecting 2 pipes that by placing a sleeve over the pipe ends secured with clamps. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
55 | Tap | Fitting placed around a pipe and secured in place with bolts to enable a tap to be inserted in the pipe. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
56 | Tapping Saddle | Fitting connection 2 different size pipes that is mounted around both sides of the larger pipe. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
57 | Tee | Fitting connection 3 pipes of the same size. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
58 | Transition | Fitting that transitions a pipe to another pipe of a different material. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
59 | Weld | Fitting that connects a pipe with a valve, fitting or flange by inserting into a recessed area. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
60 | Wye | Fitting connecting 3 pipes where a side inlet pipe joins at less than 90 degrees. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Wire Junction
The Wire Junction asset group in the WaterJunction feature class represents cathodic protection junction features that connect to pipes.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Junction_Wire_Junction | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | 1 | Bonded_Insulated | True | |
cptraceability | Cathodic Protection Traceability | SHORT | 1 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Wire Junction: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of wire junction. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
901 | Bond Junction | The location where mulitple bond wires meet and interconnect. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
902 | Test Lead | Test lead wire junction. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Insulation Junction
The Insulation Junction asset group in the Water Junction feature class represents cathodic protection junction features where the electric current stops.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Junction_Insulation_Junction | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
cptraceability | Cathodic Protection Traceability | SHORT | 2 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True |
Subtype: Insulation Junction: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of Insulation Junction. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
941 | Flange Insert | Insulation junction for inline assets with an internal or external rim used to connect two pipe segments. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
WaterLine
The Line feature class represents linear features. These are the lines which deliver your utility resource. Lines can be connected to other lines, junctions, and devices. Lines can be contained within assemblies.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Water Line | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | 0 | False | ||
assettype | Asset type | SHORT | 0 | False | ||
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
fromdeviceterminal | From device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
todeviceterminal | To device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | cpsubnetworkname: CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | systemsubnetworkname: System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | pressuresubnetworkname: Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | isolationsubnetworkname: Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | dmasubnetworkname: DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | installdate: Install Date | DATE | True | |||
assetid | assetid: Asset ID | TEXT (64) | True | |||
ownedby | ownedby: Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | maintby: Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | notes: Notes | TEXT (2000) | True | |||
diameter | diameter: Cable Gauge, Diameter, Wire Size | DOUBLE | True | |||
measuredlength | measuredlength: Measured Length | DOUBLE | True | |||
adddetails | adddetails: Color Code, Tracer Wire | SHORT | True | |||
lifecyclestatus | lifecyclestatus: Lifecycle Status | SHORT | 0 | Lifecycle_Combined | False | |
bondedinsulated | bondedinsulated: Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | cptraceability: Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | inservicedate: In-Service Date | DATE | True | |||
retireddate | retireddate: Retired Date | DATE | True | |||
material | material: Material | SHORT | True | |||
cpoverride | cpoverride: Cathodic Protection Override | SHORT | CP_Traceability | True | ||
designtype | designtype: Water Type | SHORT | True | |||
spatialsource | spatialsource: Spatial Source | SHORT | Spatial_Source | True | ||
spatialconfidence | spatialconfidence: Spatial Confidence | SHORT | Spatial_Confidence | True | ||
shape_length | shape_Length | DOUBLE | True |
Subtypes
Code | Name | Description |
---|---|---|
0 | Unknown | The Unknown asset group in the WaterLine feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. |
1 | Water Main | The Main asset group in the WaterLine feature class represents pipes with a role of distribution, transmission, or production. |
2 | Service | The Service asset group in the WaterLine feature class represents pipes providing service to devices. |
50 | Bonding Line | The Bonding Line asset group in the WaterLine feature class represensts cathodic protection with a line feature connecting protected and non protected features. |
51 | Test Lead Wire | The Test Lead Wire asset group in the WaterLine Feature class represents cathodic protection connecting from the test point to protected pipes. |
52 | Rectifier Cable | The Rectifier Cable asset group in the WaterLine Feature class represents cathodic protation wire that connects the rectifier to pipe. |
Subtype: Unknown
The Unknown asset group in the WaterLine feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Water_6_UnknownAssetType | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
fromdeviceterminal | From device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
todeviceterminal | To device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
diameter | Cable Gauge, Diameter, Wire Size | DOUBLE | True | |||
measuredlength | Measured Length | DOUBLE | True | |||
adddetails | Color Code, Tracer Wire | SHORT | True | |||
lifecyclestatus | Lifecycle Status | SHORT | False | |||
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
material | Material | SHORT | True | |||
cpoverride | Cathodic Protection Override | SHORT | True | |||
designtype | Water Type | SHORT | True | |||
spatialsource | Spatial Source | SHORT | True | |||
spatialconfidence | Spatial Confidence | SHORT | True |
Subtype: Unknown: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | The Unknown asset group in the WaterLine feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Water Main
The Main asset group in the WaterLine feature class represents pipes with a role of distribution, transmission, or production.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset Group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Line_Water_Main | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
fromdeviceterminal | From device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
todeviceterminal | To device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
shape | Shape | GEOMETRY | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
diameter | Diameter | DOUBLE | Water_Main_Diameter | True | ||
measuredlength | Measured Length | DOUBLE | True | |||
adddetails | Tracer Wire | SHORT | 0 | Yes_No | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
material | Material | SHORT | 0 | Water_Main_Material | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True | ||
designtype | Water Type | SHORT | 1 | Water_Type | True | |
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Water Main: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of water main. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
1 | Transmission Main | Transmission main. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
2 | Distribution Main | Distribution main. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
3 | Production | Production main. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
Subtype: Service
The Service asset group in the WaterLine feature class represents pipes providing service to devices.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset Group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Line_Service | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
fromdeviceterminal | From device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
todeviceterminal | To device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
shape | Shape | GEOMETRY | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
diameter | Diameter | DOUBLE | Water_Service_Diameter | True | ||
measuredlength | Measured Length | DOUBLE | True | |||
adddetails | Tracer Wire | SHORT | 0 | Yes_No | True | |
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
material | Material | SHORT | 0 | Water_Service_Material | True | |
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True | ||
designtype | Water Type | SHORT | 1 | Water_Type | True | |
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Service: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of service. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
11 | Residential Service | Residential service line . | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
12 | Commercial Service | Commercial service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
13 | Industrial Service | Industrial service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
14 | Fire Service | Fire service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
15 | Hydrant Service | Hydrant service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
16 | Irrigation Service | Irrigation service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
17 | Sampling Service | Sampling service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
18 | Blow Off Service | Blow off service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
19 | Air and Vacuum Service | Air and vacuum service line. | Single terminal | [] | NONE | DO_NOT_SPLIT | ANY_VERTEX |
Subtype: Bonding Line
The Bonding Line asset group in the WaterLine feature class represensts cathodic protection with a line feature connecting protected and non protected features.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Line_Bonding_Line | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
fromdeviceterminal | From device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
todeviceterminal | To device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
diameter | Wire Size | DOUBLE | CP_Wire_Gauge | True | ||
measuredlength | Measured Length | DOUBLE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Combined | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True | ||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Bonding Line: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of bonding line. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
941 | Wire | Wire bonding line. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
942 | Strap | Strap bonding line. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Test Lead Wire
The Test Lead Wire asset group in the WaterLine Feature class represents cathodic protection connecting from the test point to protected pipes.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Line_Test_Lead_Wire | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
fromdeviceterminal | From device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
todeviceterminal | To device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | CP Subnetwork Name | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | System Subnetwork Name | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | Pressure Subnetwork Name | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | Isolation Subnetwork Name | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | DMA Subnetwork Name | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
diameter | Cable Gauge | DOUBLE | CP_Wire_Gauge | True | ||
measuredlength | Measured Length | DOUBLE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Combined | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True | ||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Test Lead Wire: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type of test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
901 | Aqua | Aqua test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
902 | Blue | Blue test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
903 | Forest | Forest test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
904 | Green | Green test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
905 | Lavender | Lavender test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
906 | Orange | Orange test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
907 | Pink | Pink test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
908 | Red | Red test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
909 | Yellow | Yellow test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
910 | Purple | Purple test lead wire. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Rectifier Cable
The Rectifier Cable asset group in the WaterLine Feature class represents cathodic protation wire that connects the rectifier to pipe.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Water_Line_Rectifier_Cable | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
isconnected | Is connected | SHORT | 2 | Water_6_IsConnected | False | |
fromdeviceterminal | From device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
todeviceterminal | To device terminal | SHORT | 0 | Water_6_TerminalNames | False | |
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
cpsubnetworkname | cpsubnetworkname | TEXT (2000) | Unknown | False | ||
systemsubnetworkname | systemsubnetworkname | TEXT (2000) | Unknown | False | ||
pressuresubnetworkname | pressuresubnetworkname | TEXT (2000) | Unknown | False | ||
isolationsubnetworkname | isolationsubnetworkname | TEXT (2000) | Unknown | False | ||
dmasubnetworkname | dmasubnetworkname | TEXT (2000) | Unknown | False | ||
installdate | Install Date | DATE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
ownedby | Owned By | SHORT | 1 | Asset_Owner | True | |
maintby | Maintained By | SHORT | 1 | Asset_Manager | True | |
notes | Notes | TEXT (2000) | True | |||
diameter | Cable Gauge, Diameter, Wire Size | DOUBLE | CP_Wire_Gauge | True | ||
measuredlength | Measured Length | DOUBLE | True | |||
adddetails | Tracer Wire | SHORT | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 0 | Lifecycle_Combined | False | |
bondedinsulated | Bonded/Insulated | SHORT | Bonded_Insulated | True | ||
cptraceability | Cathodic Protection Traceability | SHORT | 0 | Yes_No | True | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
material | Material | SHORT | True | |||
cpoverride | Cathodic Protection Override | SHORT | CP_Traceability | True | ||
designtype | Water Type | SHORT | True | |||
spatialsource | Spatial Source | SHORT | Spatial_Source | True | ||
spatialconfidence | Spatial Confidence | SHORT | Spatial_Confidence | True |
Subtype: Rectifier Cable: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Unknown type or rectifier cable. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
961 | Rectifier Cable | Rectifier cable used for connecting rectifier to pipe for cathodic protection. | Single terminal | ['CP Only'] | NONE | DO_NOT_SPLIT | END_VERTEX |
WaterSubnetLine
The system maintained set of subnetworks.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Water Subnet Line | False |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
subnetworkname | Subnetwork name | TEXT (64) | Unknown | False | ||
isdirty | Is dirty | SHORT | 0 | Water_6_IsDirty | False | |
tiername | Tier name | LONG | 0 | False | ||
subnetworkcontrollernames | Subnetwork controller names | TEXT (2000) | Unknown | False | ||
lastupdatesubnetwork | Last update subnetwork | DATE | True | |||
lastackexportsubnetwork | Last ack export subnetwork | DATE | True | |||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
serviceconcnt | Service Connection Count | LONG | True | |||
subnetworklength | Subnetwork Length | DOUBLE | True | |||
hydrantcnt | Hydrant Count | LONG | True | |||
servlvcnt | Service Valve Count | LONG | True | |||
protcnt | Protective Device Count | LONG | True | |||
distsubnetworklength | Distribution Subnetwork Length | DOUBLE | True | |||
transsubnetworklength | Transmission Subnetwork Length | DOUBLE | True | |||
shape_length | shape_Length | DOUBLE | True |
Subtypes
Code | Name | Description |
---|---|---|
0 | Unknown | The Unknown asset group in the WaterSubnetLine feature class represents the network of lines that have an unknown subnetwork. |
1 | Water Cathodic Protection | The Cathodic Protection asset group in the WaterSubnetLine feature class represents the network of lines that are part of the Cathodic Protection subnetwork. |
2 | Water System | The System asset group in the WaterSubnetLine feature class represents the network of lines that are part of the System subnetwork. |
3 | Water Pressure | The Pressure asset group in the WaterSubnetLine feature class represents the network of lines that are part of the Pressure subnetwork. |
4 | Water Isolation | The Isolation asset group in the WaterSubnetLine feature class represents the network of lines that are part of the Isolation subnetwork. |
5 | Water District Metered Areas (DMAs) | The District Metered Areas (DMAs) asset group in the WaterSubnetLine feature class represents the network of lines that are part of the District Metered Areas (DMAs) subnetwork. |
Subtype: Unknown
The Unknown asset group in the WaterSubnetLine feature class represents the network of lines that have an unknown subnetwork.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|
Subtype: Water Cathodic Protection
The Cathodic Protection asset group in the WaterSubnetLine feature class represents the network of lines that are part of the Cathodic Protection subnetwork.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|
Subtype: Water System
The System asset group in the WaterSubnetLine feature class represents the network of lines that are part of the System subnetwork.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|
Subtype: Water Pressure
The Pressure asset group in the WaterSubnetLine feature class represents the network of lines that are part of the Pressure subnetwork.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|
Subtype: Water Isolation
The Isolation asset group in the WaterSubnetLine feature class represents the network of lines that are part of the Isolation subnetwork.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|
Subtype: Water District Metered Areas (DMAs)
The District Metered Areas (DMAs) asset group in the WaterSubnetLine feature class represents the network of lines that are part of the District Metered Areas (DMAs) subnetwork.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|
Utility Network Structure Feature Classes
StructureBoundary
The Structure Boundary feature class represents features whose outline should be display on a map view or container view. Structure boundaries can contain structure edges, structure junctions, devices, lines, assemblies, and junctions.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Structure Boundary | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | 0 | False | ||
assettype | Asset type | SHORT | 0 | False | ||
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | name: Name | TEXT (64) | True | |||
assetid | assetid: Asset ID | TEXT (64) | True | |||
lifecyclestatus | lifecyclestatus: Lifecycle Status | SHORT | 0 | Lifecycle_Combined | False | |
installdate | installdate: Install Date | DATE | True | |||
inservicedate | inservicedate: In-Service Date | DATE | True | |||
retireddate | retireddate: Retired Date | DATE | True | |||
spatialsource | spatialsource: Spatial Source | SHORT | Spatial_Source | True | ||
spatialconfidence | spatialconfidence: Spatial Confidence | SHORT | Spatial_Confidence | True | ||
notes | notes: Notes | TEXT (2000) | True | |||
shape_length | shape_Length | DOUBLE | True | |||
shape_area | shape_Area | DOUBLE | True |
Subtypes
Code | Name | Description |
---|---|---|
0 | Unknown | The Unknown asset group in the StructureBoundary feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. |
503 | Water Storage Boundary | The Water Storage Boundary asset group in the StructureBoundary feature class represents the boundary of areas that store water as a polygon feature. |
505 | Water Pump Station Boundary | The Water Pump Station Boundary asset group in the StructureBoundary feature class represents the boundary of water pump stations as a polygon feature. |
507 | Water Supply Boundary | The Water Supply Boundary asset group in the StructureBoundary feature class represents the boundary of water treatment plants and wells as a polygon feature. |
508 | Water Vault Boundary | The Water Vault Boundary asset group in the StructureBoundary feature class represents the boundary of underground structures as a polygon feature. |
509 | Water Valve Box Boundary | The Water Valve Box Boundary asset group in the StructureBoundary feature class represents the boundary of a water valve box as a polygon feature. |
Subtype: Unknown
The Unknown asset group in the StructureBoundary feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Water_6_UnknownAssetType | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | Name | TEXT (64) | True | |||
assetid | Asset ID | TEXT (64) | True | |||
lifecyclestatus | Lifecycle Status | SHORT | False | |||
installdate | Install Date | DATE | True | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | True | |||
spatialconfidence | Spatial Confidence | SHORT | True | |||
notes | Notes | TEXT (2000) | True |
Subtype: Unknown: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | The Unknown asset group in the StructureBoundary feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Water Storage Boundary
The Water Storage Boundary asset group in the StructureBoundary feature class represents the boundary of areas that store water as a polygon feature.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Structure_Boundary_Water_Storage_Boundary | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | Name | TEXT (64) | True | |||
assetid | Asset ID | TEXT (64) | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
installdate | Install Date | DATE | True | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
notes | Notes | TEXT (2000) | True |
Subtype: Water Storage Boundary: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | An polygon feature representing an unknown type of water storage boundary. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
1 | Reservoir | Polygon feature representing the structure boundary of reservoir. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
2 | Retention Area | Polygon feature representing the structure boundary of a water retention basin. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
3 | Storage Tank | Polygon feature representing the structure boundary of a water storage tank. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
4 | Tower | Polygon feature representing the structure boundary of a water storage tower. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
5 | Surge Tank | Polygon feature representing the structure boundary of a water surge tank. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
6 | Hydropneumatic Tank | Polygon feature representing the structure boundary of a water hydropneumatic tank. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Water Pump Station Boundary
The Water Pump Station Boundary asset group in the StructureBoundary feature class represents the boundary of water pump stations as a polygon feature.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Structure_Boundary_Water_Pump_Station_Boundary | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | Name | TEXT (64) | True | |||
assetid | Asset ID | TEXT (64) | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
installdate | Install Date | DATE | True | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
notes | Notes | TEXT (2000) | True |
Subtype: Water Pump Station Boundary: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Polygon feature representing the structure boundary of a unknown type of pump station. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
41 | Pump Station | Polygon feature representing the structure boundary of a pump station. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
42 | Booster Station | Polygon feature representing the structure boundary of a booster pump station. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Water Supply Boundary
The Water Supply Boundary asset group in the StructureBoundary feature class represents the boundary of water treatment plants and wells as a polygon feature.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Structure_Boundary_Water_Supply_Boundary | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | Name | TEXT (64) | True | |||
assetid | Asset ID | TEXT (64) | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
installdate | Install Date | DATE | True | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
notes | Notes | TEXT (2000) | True |
Subtype: Water Supply Boundary: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Polygon feature representing the structure boundary of a unknown water supply feature. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
81 | Treatment Plant | Polygon feature representing the structure boundary a water treatment plant. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
82 | Well | Polygon feature representing the structure boundary of a well. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
83 | Interconnect | Polygon feature representing the structure boundary of an interconnection with another water service provider. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Water Vault Boundary
The Water Vault Boundary asset group in the StructureBoundary feature class represents the boundary of underground structures as a polygon feature.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Structure_Boundary_Water_Vault_Boundary | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
assetid | Asset ID | TEXT (64) | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
installdate | Install Date | DATE | True | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
notes | Notes | TEXT (2000) | True |
Subtype: Water Vault Boundary: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Polygon feature representing the structure boundary of unknown type of water vault. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
121 | Air Release Valve | Polygon feature representing the structure boundary of an air release valve. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
122 | Blow Off | Polygon feature representing the structure boundary of a blow off. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
123 | Meter Pit | Polygon feature representing the structure boundary of a meter pit. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Subtype: Water Valve Box Boundary
The Water Valve Box Boundary asset group in the StructureBoundary feature class represents the boundary of a water valve box as a polygon feature.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | Asset_Type_Structure_Boundary_Water_Valve_Box_Boundary | False | ||
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | Name | TEXT (64) | True | |||
assetid | Asset ID | TEXT (64) | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
installdate | Install Date | DATE | True | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True | |
notes | Notes | TEXT (2000) | True |
Subtype: Water Valve Box Boundary: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Polygon feature representing the structure boundary of unknown type of water valve box. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
61 | Curb Box | Polygon feature representing the structure boundary of a curb box. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
62 | Curb Box with Stationary Rod | Polygon feature representing the structure boundary of a curb box with stationary rod. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
63 | Roadway | Polygon feature representing the structure boundary of a roadway. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
64 | Valve Box | Polygon feature representing the structure boundary of a valve box. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
StructureJunction
The Structure Junction feature class represents features which are tracked in a utility's asset inventory system. A structure junction can be either a structural feature that a device is attached to or a container of devices.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Structure Junction | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | 0 | False | ||
assettype | Asset type | SHORT | 0 | False | ||
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | name: Name | TEXT (64) | True | |||
assetid | assetid: Asset ID | TEXT (64) | True | |||
dimension | dimension: Dimension | SHORT | True | |||
depth | depth: Depth | DOUBLE | True | |||
notes | notes: Notes | TEXT (2000) | True | |||
symbolrotation | symbolrotation: Symbol Rotation | SHORT | Symbol_Rotation | True | ||
installdate | installdate: Install Date | DATE | True | |||
lifecyclestatus | lifecyclestatus: Lifecycle Status | SHORT | 0 | Lifecycle_Combined | False | |
inservicedate | inservicedate: In-Service Date | DATE | True | |||
retireddate | retireddate: Retired Date | DATE | True | |||
spatialsource | spatialsource: Spatial Source | SHORT | Spatial_Source | True | ||
spatialconfidence | spatialconfidence: Spatial Confidence | SHORT | Spatial_Confidence | True |
Subtypes
Code | Name | Description |
---|---|---|
0 | Unknown | The Unknown asset group in the StructureJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. |
501 | Water Access Point | The Water Access Point asset group in the StructureJunction feature class represents covers or doors that provide access to underground structures as point features. |
Subtype: Unknown
The Unknown asset group in the StructureJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Water_6_UnknownAssetType | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | Name | TEXT (64) | True | |||
assetid | Asset ID | TEXT (64) | True | |||
dimension | Dimension | SHORT | True | |||
depth | Depth | DOUBLE | True | |||
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | True | |||
installdate | Install Date | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | False | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | True | |||
spatialconfidence | Spatial Confidence | SHORT | True |
Subtype: Unknown: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | The Unknown asset group in the StructureJunction feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Water Access Point
The Water Access Point asset group in the StructureJunction feature class represents covers or doors that provide access to underground structures as point features.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Structure_Junction_Water_Access_Point | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
name | Name | TEXT (64) | True | |||
assetid | Asset ID | TEXT (64) | True | |||
dimension | Dimension | SHORT | 0 | Water_Access_Point_Size | True | |
depth | Depth | DOUBLE | 0 | Water_Access_Point_Depth | True | |
notes | Notes | TEXT (2000) | True | |||
symbolrotation | Symbol Rotation | SHORT | Symbol_Rotation | True | ||
installdate | Install Date | DATE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Water Access Point: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Point feature representing an unknown structure that provides access to the water distribution network. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
122 | Manhole Cover | Point feature representing a manhole cover that provides access to the water distribution network. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
124 | Door | Point feature that represents a door that provides access to the water distribution network. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
125 | Grate | Point feature that represents a grate that provides access to the water distribution network. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
126 | Hand Hole | Point feature that represents a hand hole that provides access to the water distribution network. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
127 | Lid | Point feature that represents a lid that provides access to the water distribution network. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
StructureLine
The Structure Line contain lines which carry a resource. Structure lines participating as containers can contain other structure lines.
Class Details
DatasetType | ShapeType | Alias | Has Attachment |
---|---|---|---|
FEATURE_CLASS | SIMPLE | Structure Line | True |
Fields
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | 0 | False | ||
assettype | Asset type | SHORT | 0 | False | ||
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
measuredlength | measuredlength: Measured Length | DOUBLE | True | |||
assetid | assetid: Asset ID | TEXT (64) | True | |||
diameter | diameter: Diameter | DOUBLE | True | |||
lifecyclestatus | lifecyclestatus: Lifecycle Status | SHORT | 0 | Lifecycle_Combined | False | |
installdate | installdate: Install Date | DATE | True | |||
inservicedate | inservicedate: In-Service Date | DATE | True | |||
retireddate | retireddate: Retired Date | DATE | True | |||
spatialsource | spatialsource: Spatial Source | SHORT | Spatial_Source | True | ||
spatialconfidence | spatialconfidence: Spatial Confidence | SHORT | Spatial_Confidence | True | ||
shape_length | shape_Length | DOUBLE | True |
Subtypes
Code | Name | Description |
---|---|---|
0 | Unknown | The Unknown asset group in the StructureLine feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. |
501 | Water Casing | The Water Casing asset group in the StructureLine feature class represents features that enclose or case water mains as a line feature. |
Subtype: Unknown
The Unknown asset group in the StructureLine feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Water_6_UnknownAssetType | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
measuredlength | Measured Length | DOUBLE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
diameter | Diameter | DOUBLE | True | |||
lifecyclestatus | Lifecycle Status | SHORT | False | |||
installdate | Install Date | DATE | True | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | True | |||
spatialconfidence | Spatial Confidence | SHORT | True |
Subtype: Unknown: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | The Unknown asset group in the StructureLine feature class is used for data migration and is not intended to store known assets. It does not have any rules or network properties applied to it. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
Subtype: Water Casing
The Water Casing asset group in the StructureLine feature class represents features that enclose or case water mains as a line feature.
Name | Alias | Type | Default Value | Domain | Nullable | Description |
---|---|---|---|---|---|---|
objectid | Object ID | OID | False | |||
assetgroup | Asset group | LONG | False | |||
assettype | Asset type | SHORT | 0 | Asset_Type_Structure_Line_Water_Casing | False | |
associationstatus | Association status | SHORT | 0 | Water_6_AssociationStatus | False | |
subnetworkname | Subnetwork name | TEXT (2000) | Unknown | False | ||
creationdate | Creation date | DATE | True | |||
creator | Creator | TEXT (255) | True | |||
lastupdate | Last update | DATE | True | |||
updatedby | Updated by | TEXT (255) | True | |||
shape | Shape | GEOMETRY | False | |||
globalid | Global ID | GUID | False | |||
measuredlength | Measured Length | DOUBLE | True | |||
assetid | Asset ID | TEXT (64) | True | |||
diameter | Diameter | DOUBLE | Water_Casing_Diameters | True | ||
lifecyclestatus | Lifecycle Status | SHORT | 8 | Lifecycle_Status | False | |
installdate | Install Date | DATE | True | |||
inservicedate | In-Service Date | DATE | True | |||
retireddate | Retired Date | DATE | True | |||
spatialsource | Spatial Source | SHORT | 0 | Spatial_Source | True | |
spatialconfidence | Spatial Confidence | SHORT | 0 | Spatial_Confidence | True |
Subtype: Water Casing: Asset Types
Code | Name | Description | terminalConfigurationName | categories | associationRoleType | splitContent | connectivityPolicy |
---|---|---|---|---|---|---|---|
0 | Unknown | Linear feature representing an unknown material type casing for the water distribution network. | Single terminal | [] | NONE | DO_NOT_SPLIT | END_VERTEX |
1 | Cast Iron - CAS | Linear feature representing a cast iron casing for the water distribution network. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
2 | Ductile Iron - DI | Linear feature representing a ductile iron casing for the water distribution network. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
3 | Polyvinyl Chloride - PVC | Linear feature representing a polyvinyl chloride casing for the water distribution network. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
4 | Steel - SP | Linear feature representing a steel casing for the water distribution network. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
5 | Concrete (Non-reinforced) - CP | Linear feature representing a non-reinforced concrete casing for the water distribution network. | Single terminal | [] | CONTAINER | DO_NOT_SPLIT | END_VERTEX |
Attribute Domains
AP_Category_Configure
List of configurations
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|
Asset_Manager
The manager of the asset.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
1 | Our Agency | |
2 | Private | |
100 | Other |
Asset_Owner
The owner of the asset.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
1 | Our Agency | |
2 | Private | |
100 | Other |
Asset_Type_Structure_Boundary_Water_Pump_Station_Boundary
The Asset Types for the Structure Boundary's Asset Group Water Pump Station
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
41 | Pump Station | |
42 | Booster Station |
Asset_Type_Structure_Boundary_Water_Storage_Boundary
The Asset Types for the Structure Boundary's Asset Group Water Storage
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Reservoir | |
2 | Retention Area | |
3 | Storage Tank | |
4 | Tower | |
5 | Surge Tank | |
6 | Hydropneumatic Tank |
Asset_Type_Structure_Boundary_Water_Supply_Boundary
The Asset Types for the Structure Boundary's Asset Group Water Supply
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
81 | Treatment Plant | |
82 | Well | |
83 | Interconnect |
Asset_Type_Structure_Boundary_Water_Valve_Box_Boundary
The Asset Types for the Structure Boundary's Asset Group Water Valve Box
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
61 | Curb Box | |
62 | Curb Box with Stationary Rod | |
63 | Roadway | |
64 | Valve Box |
Asset_Type_Structure_Boundary_Water_Vault_Boundary
The Asset Types for the Structure Boundary's Asset Group Water Vault Footprint
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
121 | Air Release Valve | |
122 | Blow Off | |
123 | Meter Pit |
Asset_Type_Structure_Junction_Water_Access_Point
The Asset Types for the Structure Junction's Asset Group Water Access Point
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
122 | Manhole Cover | |
124 | Door | |
125 | Grate | |
126 | Hand Hole | |
127 | Lid |
Asset_Type_Structure_Line_Water_Casing
The Asset Types for the Structure Line's Asset Group Water Casing
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Cast Iron - CAS | |
2 | Ductile Iron - DI | |
3 | Polyvinyl Chloride - PVC | |
4 | Steel - SP | |
5 | Concrete (Non-reinforced) - CP |
Asset_Type_Water_Assembly_Air_Vacuum_and_Air_Release
The Asset Types for the Water Assembly's Asset Group Air Vacuum & Air Release
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
201 | Air Vacuum and Air Release |
Asset_Type_Water_Assembly_Backflow
The Asset Types for the Water Assembly's Asset Group Backflow
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Double Check Detector | |
2 | Double Check Valve | |
3 | Reduced Pressure Detector | |
4 | Reduced Pressure Zone |
Asset_Type_Water_Assembly_Blow_Off
The Asset Types for the Water Assembly's Asset Group Blow Off
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
41 | Automatic | |
42 | Manual |
Asset_Type_Water_Assembly_Horizontal_Valve
The Asset Types for the Water Assembly's Asset Group Horizontal Valve
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
121 | Operator Nut | |
122 | Operator Nut and Bypass Valve |
Asset_Type_Water_Assembly_Hydrant
The Asset Types for the Water Assembly's Asset Group Hydrant
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
241 | Fire Hydrant |
Asset_Type_Water_Assembly_Meter_Station
The Asset Types for the Water Assembly's Asset Group Meter Station
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
81 | Meter Station |
Asset_Type_Water_Assembly_Pressure_Reducing_Station
The Asset Types for the Water Assembly's Asset Group Pressure Reducing Station
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
161 | Pressure Reducing Station |
Asset_Type_Water_Device_Anode
The Asset Types for the Water Device's Asset Group Anode
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
901 | ICCP | |
902 | Galvanic |
Asset_Type_Water_Device_Controllable_Valve
The Asset Types for the Water Device's Asset Group Controllable Valve
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
161 | Blow Off | |
164 | Hydrant | |
167 | Isolation Zone | |
169 | Supply | |
170 | System | |
171 | Sampling | |
172 | Pressure Zone | |
173 | Bypass | |
174 | Purge | |
175 | Interconnect | |
176 | Service |
Asset_Type_Water_Device_Controller
The Asset Types for the Water Device's Asset Group Controller
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
121 | Bypass Valve | |
122 | Operator Nut |
Asset_Type_Water_Device_Filter
The Asset Types for the Water Device's Asset Group Filter
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
81 | Strainer |
Asset_Type_Water_Device_Fire_Hydrant
The Asset Types for the Water Device's Asset Group Fire Hydrant
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
321 | Fire Hydrant |
Asset_Type_Water_Device_Flow_Valve
The Asset Types for the Water Device's Asset Group Flow Valve
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Air Gap | |
2 | Altitude | |
3 | Check |
Asset_Type_Water_Device_Flushing_and_Blow_Off
The Asset Types for the Water Device's Asset Group Flushing and Blow Off
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
361 | Automatic Flushing | |
362 | Fire Plug Valve | |
363 | Hydrant | |
364 | Post Hydrant | |
365 | Blow Off |
Asset_Type_Water_Device_Injection_Facility
The Asset Types for the Water Device's Asset Group Injection Facility
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
401 | Chlorination | |
402 | Fluoridation |
Asset_Type_Water_Device_Meter
The Asset Types for the Water Device's Asset Group Meter
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
41 | Bulk | |
42 | Commercial | |
43 | DMA | |
44 | Emergency Connection | |
45 | Industrial | |
46 | Master | |
47 | Pump Station | |
48 | Residential |
Asset_Type_Water_Device_Monitoring
The Asset Types for the Water Device's Asset Group Monitoring
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
21 | Observation Well | |
22 | Pressure Sensor | |
23 | Temperature Sensor | |
24 | Detection Meter |
Asset_Type_Water_Device_Outlet
The Asset Types for the Water Device's Asset Group Outlet
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
641 | Outlet | |
642 | Yard Hydrant |
Asset_Type_Water_Device_Pressure_Valve
The Asset Types for the Water Device's Asset Group Pressure Valve
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
201 | Air and Vacuum | |
202 | Air Release | |
203 | Combination Air | |
204 | Pressure Limiting | |
205 | Pressure Reducing | |
206 | Pressure Release | |
207 | Pressure Sustaining |
Asset_Type_Water_Device_Pump
The Asset Types for the Water Device's Asset Group Pump
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
281 | Booster | |
282 | Chemical | |
283 | Primary |
Asset_Type_Water_Device_Rectifier
The Asset Types for the Water Device Asset Group Rectifier
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
941 | Rectifier |
Asset_Type_Water_Device_Service_Connection
The Asset Types for the Water Junction's Asset Group Service Connection
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
61 | Commercial | |
62 | Fire | |
63 | Industrial | |
64 | Irrigation | |
65 | Residential |
Asset_Type_Water_Device_Station
The Asset Types for the Water Device's Asset Group Station
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
241 | Sample Station |
Asset_Type_Water_Device_Storage
The Asset Types for the Water Device's Asset Group Storage
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
561 | Reservoir | |
562 | Standpipe | |
563 | Storage Tank | |
564 | Tower | |
565 | Surge Tank | |
566 | Hydropneumatic Tank |
Asset_Type_Water_Device_Supply
The Asset Types for the Water Device's Asset Group Supply
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
601 | Treatment Plant | |
602 | Well | |
603 | Interconnect |
Asset_Type_Water_Device_Test_Point
The Asset Types for the Water Device's Asset Group Test Point
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
981 | Test Point |
Asset_Type_Water_Junction_Fitting
The Asset Types for the Water Junction's Asset Group Fitting
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
41 | Corporation Stop | |
42 | Coupling | |
43 | Cross | |
44 | Elbow | |
45 | End Cap | |
46 | Expansion Joint | |
47 | Flange | |
48 | Plug | |
49 | Reducer | |
50 | Reducing Cross | |
51 | Reducing Tee | |
52 | Saddle | |
53 | Screw | |
54 | Sleeve | |
55 | Tap | |
56 | Tapping Saddle | |
57 | Tee | |
58 | Transition | |
59 | Weld | |
60 | Wye |
Asset_Type_Water_Junction_Insulation_Junction
The Asset Types for the Water Junction's Asset Group Insulation Junction
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
941 | Flange Insert |
Asset_Type_Water_Junction_Wire_Junction
The Asset Types for the Water Junction's Asset Group Wire Junction
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
901 | Bond Junction | |
902 | Test Lead |
Asset_Type_Water_Line_Bonding_Line
The Asset Types for the Water Line's Asset Group Bonding Line
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
941 | Wire | |
942 | Strap |
Asset_Type_Water_Line_Rectifier_Cable
The Asset Types for the Water Line's Asset Group Rectifier Cable
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
961 | Rectifier Cable |
Asset_Type_Water_Line_Service
The Asset Types for the Water Line's Asset Group Service
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
11 | Residential Service | |
12 | Commercial Service | |
13 | Industrial Service | |
14 | Fire Service | |
15 | Hydrant Service | |
16 | Irrigation Service | |
17 | Sampling Service | |
18 | Blow Off Service | |
19 | Air and Vacuum Service |
Asset_Type_Water_Line_Test_Lead_Wire
The Asset Types for the Water Line's Asset Group Rectifier Cables
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
901 | Aqua | |
902 | Blue | |
903 | Forest | |
904 | Green | |
905 | Lavender | |
906 | Orange | |
907 | Pink | |
908 | Red | |
909 | Yellow | |
910 | Purple |
Asset_Type_Water_Line_Water_Main
The Asset Types for the Water Line's Asset Group Water Main
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Transmission Main | |
2 | Distribution Main | |
3 | Production |
Bonded_Insulated
Values to indicate if a feature is bonded or insulated
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
1 | Bonded | |
2 | Insulated |
Boolean
True or False
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | False | |
1 | True |
CP_Anode_Material
List of materials used for Anodes
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
11 | Carbon-Graphite | |
12 | Cast Iron | |
13 | Galvanic | |
14 | Graphite | |
15 | Magnesium | |
16 | Magnesium (High Grade B) | |
17 | Magnesium (High Potential) | |
18 | Mixed Metal Oxide | |
19 | Scrap Steel | |
20 | Zinc |
CP_Anode_Weight
List of valid anode weights
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
0.75 | 3/4 lb | |
1 | 1 lb | |
1.5 | 1.5 lb | |
3 | 3 lb | |
5 | 5 lb | |
9 | 9 lb | |
17 | 17 lb | |
20 | 20 lb | |
32 | 32 lb | |
48 | 48 lb |
CP_Rectifier_Cooling_Method
List of rectifier cooling methods
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
21 | Fan Cooling | |
22 | Convection Cooling | |
23 | System Cooling | |
24 | Assisted Cooling |
CP_Rectifier_Manufacturer
List of manufacturers for rectifiers
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
80 | Goodall | |
81 | Kerotest | |
82 | Rockwell | |
83 | R.W. Lyall |
CP_Test_Point_Wire_Count
Number of wires on a test point
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | 1 | |
2 | 2 | |
3 | 3 | |
4 | 4 | |
5 | 5 | |
6 | 6 | |
7 | 7 | |
8 | 8 |
CP_Traceability
Valid cathodic protection status values
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
1 | Traceable | |
2 | Not Traceable |
CP_Wire_Gauge
List of valid sizes used for wire/cable gauges
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
4 | 4 | |
8 | 8 |
Lifecycle_Combined
Bitwise combination of lifecycle states for subnetwork management
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Proposed | |
2 | Approved | |
3 | Proposed and Approved | |
4 | Under Construction | |
6 | Approved and Under Construction | |
7 | Proposed, Approved and Under Construction | |
8 | In Service | |
12 | In Service and Under Construction | |
14 | In Service, Under Construction, and Approved | |
15 | In Service, Under Construction, Approved and Proposed | |
16 | To Be Retired | |
24 | In Service and To Be Retired | |
32 | Abandoned | |
64 | Retired | |
128 | Removed | |
256 | Out of Service |
Lifecycle_Status
Valid lifecycle states for the assets.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Proposed | |
2 | Approved | |
4 | Under Construction | |
8 | In Service | |
16 | To Be Retired | |
32 | Abandoned | |
64 | Retired | |
128 | Removed | |
256 | Out of Service |
Pipeline_Device_Status
Status of device
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
2 | Inactive | |
3 | Active |
Pipeline_Device_Status_Combined
The status or state of a device
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Closed | |
1 | Open | |
2 | Inactive | |
3 | Active |
Pipeline_Valve_Close_Direction
The close direction of a valve
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Counter Clockwise | |
1 | Clockwise |
Pipeline_Valve_Status
The status of a water device
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Closed | |
1 | Open |
Spatial_Confidence
Confidence values for the data
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | High | |
2 | Medium | |
3 | Low |
Spatial_Source
Source of the data
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | As-Built | |
2 | CAD | |
3 | Digitized | |
4 | GPS/GNSS | |
5 | Field Sketch |
Symbol_Rotation
Valid rotation values
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Min | Max |
---|---|
0 | 359 |
Water_6_AssociationStatus
Indicates how the feature participates in associations.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | None | |
1 | Container | |
2 | Structure | |
4 | Content | |
5 | Content and Container | |
6 | Content and Structure | |
8 | Attachment | |
9 | Attachment and Container | |
12 | Attachment and Content | |
13 | Attachment and Content and Container | |
16 | Visible Content | |
17 | Visible Content and Container | |
18 | Visible Content and Structure | |
24 | Visible Content and Attachment | |
25 | Visible Content and Attachment and Container | |
32 | Connectivity | |
36 | Connectivity and Content | |
40 | Connectivity and Attachment | |
44 | Connectivity and Attachment and Content | |
48 | Connectivity and Visible Content | |
56 | Connectivity and Visible Content and Attachment |
Water_6_FeatureSourceID
The source feature class name in the utility network.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Association | |
2 | System Junction | |
3 | Structure Junction | |
4 | Structure Line | |
5 | Structure Boundary | |
6 | Water Device | |
7 | Water Line | |
8 | Water Assembly | |
9 | Water Junction | |
10 | Water Subnet Line |
Water_6_IsConnected
Indicates if the feature is connected to a subnetwork controller.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | False | |
1 | True | |
2 | Unknown |
Water_6_IsContentVisible
Indicates if the content or attachment association is visible for containment associations.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | False | |
1 | True |
Water_6_IsDeleted
Indicates if a subnetwork has been marked for deletion.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | False | |
1 | True |
Water_6_IsDirty
Indicates if a subnetwork is dirty.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | False | |
1 | True |
Water_6_IsSubnetworkController
Indicates if a device feature is a subnetwork controller.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | False | |
1 | True |
Water_6_TerminalNames
The terminal names in the utility network.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | None | |
1 | Single Terminal | |
2 | High Pressure In | |
3 | Low Pressure Out | |
4 | Low Pressure In | |
5 | High Pressure Out | |
6 | Inlet Port | |
7 | Outlet Port | |
8 | Port One | |
9 | Port Two | |
10 | Terminal One | |
11 | Terminal Two | |
12 | Terminal Three | |
13 | Terminal Four | |
14 | Terminal Five | |
15 | Terminal Six | |
16 | Terminal Seven | |
17 | Terminal Eight |
Water_6_TierName
The tier names in the utility network.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Water Cathodic Protection | |
2 | Water System | |
3 | Water Pressure | |
4 | Water Isolation | |
5 | Water District Metered Areas (DMAs) |
Water_6_TierTopologyType
The type of topology for each tier.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
1 | Radial | |
2 | Mesh |
Water_6_UnknownAssetType
The AssetType domain for the Unknown AssetGroup.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown |
Water_6_UpdateType
Indicates what operation created the dirty area.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DEFAULT | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Insert | |
1 | Update | |
2 | Delete | |
3 | Error |
Water_Access_Point_Depth
Valid depths for water access points
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
24 | 24" | |
30 | 30" | |
36 | 36" | |
42 | 42" | |
48 | 48" |
Water_Access_Point_Size
Valid sizes for Water Access Points
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
24 | 24" | |
26 | 26" | |
222 | 22 1/4" | |
227 | 22 3/4" | |
237 | 23 3/4" | |
255 | 25 1/2" | |
316 | 31 9/16" | |
357 | 35 3/4" | |
360 | 36" | |
370 | 37" |
Water_Casing_Diameters
List of casing sizes, in Imperial units
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
10 | 10" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
30 | 30" |
Water_Diameter
General domain for the diameter of water assets, in Imperial units
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
0.5 | 1/2" | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
4 | 4" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
15 | 15" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
24 | 24" | |
30 | 30" | |
36 | 36" | |
40 | 40" | |
42 | 42" | |
48 | 48" | |
54 | 54" | |
60 | 60" | |
66 | 66" | |
72 | 72" | |
75 | 75" |
Water_Fire_Hydrant_Manufacturer
The valid hydrant manufacturers
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
60 | American Darling | |
61 | Clow Corporation | |
62 | Corey | |
63 | Dresser | |
64 | Eddy | |
65 | Iowa Valve | |
66 | Kennedy Valve | |
67 | M&H Valve | |
68 | Mueller Company | |
69 | Traverse City | |
70 | US Pipe | |
71 | Waterous | |
72 | Wood-Matthews | |
73 | Other |
Water_Fitting_Diameter
Valid Fitting sizes
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
0.25 | 1/4" | |
0.375 | 3/8" | |
0.5 | 1/2" | |
0.625 | 5/8" | |
0.75 | 3/4" | |
1 | 1" | |
1.125 | 1 1/8" | |
1.25 | 1 1/4" | |
1.375 | 1 3/8" | |
1.5 | 1 1/2" | |
1.875 | 1 7/8" | |
2 | 2" | |
2.5 | 2 1/2" | |
3 | 3" | |
4 | 4" | |
5 | 5" | |
5.5 | 5 1/2" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
24 | 24" | |
26 | 26" | |
30 | 30" | |
36 | 36" | |
40 | 40" | |
48 | 48" | |
1000 | 1" x 1/2" | |
1001 | 1" x 5/8" | |
1002 | 1" x 3/4" | |
1003 | 1 1/4" x 1/2" | |
1004 | 1 1/4" x 5/8" | |
1005 | 1 1/4" x 3/4" | |
1006 | 1 1/4" x 7/8" | |
1007 | 1 1/4" x 1" | |
1008 | 1 1/2" x 3/4" | |
1009 | 1 1/2" x 1" | |
1010 | 1 1/2" x 1 1/4" | |
1011 | 2" x 1" | |
1012 | 2" x 1 1/4" | |
1013 | 2" x 1 1/2" | |
1014 | 3" x 1 1/2" | |
1015 | 3" x 2" | |
1016 | 4" x 2" | |
1017 | 4" x 3" | |
1018 | 6" x 3" | |
1019 | 6" x 4" | |
1020 | 8" x 4" | |
1021 | 8" x 6" | |
1022 | 10" x 6" | |
1023 | 10" x 8" | |
1024 | 12" x 6" | |
1025 | 12" x 8" | |
1026 | 12" x 10" | |
1027 | 14" x 8" | |
1028 | 14" x 10" | |
1029 | 14" x 12" | |
1030 | 16" x 8" | |
1031 | 16" x 10" | |
1032 | 16" x 12" | |
1033 | 16" x 14" | |
1034 | 18" x 10" | |
1035 | 18" x 12" | |
1036 | 18" x 14" | |
1037 | 18" x 16" | |
1038 | 20" x 10" | |
1039 | 20" x 12" | |
1040 | 20" x 14" | |
1041 | 20" x 16" | |
1042 | 20" x 18" | |
1043 | 24" x 12" | |
1044 | 24" x 14" | |
1045 | 24" x 16" | |
1046 | 24" x 18" | |
1047 | 24" x 20" | |
1048 | 26" x 14" | |
1049 | 26" x 16" | |
1050 | 26" x 18" | |
1051 | 26" x 20" | |
1052 | 26" x 24" | |
1053 | 30" x 16" | |
1054 | 30" x 18" | |
1055 | 30" x 20" | |
1056 | 30" x 24" | |
1057 | 30" x 26" | |
1058 | 36" x 18" | |
1059 | 36" x 20" | |
1060 | 36" x 24" | |
1061 | 36" x 26" | |
1062 | 40" x 20" | |
1063 | 40" x 24" | |
1064 | 40" x 26" | |
1065 | 40" x 30" | |
1066 | 40" x 36" | |
1067 | 48" x 24" | |
1068 | 48" x 26" | |
1069 | 48" x 30" | |
1070 | 48" x 36" |
Water_Hydrant_Nozzle_Diameter
Sizes of a fire hydrants nozzle, in Imperial units
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
2.5 | 2 1/2" | |
4.5 | 4 1/2" | |
5 | 5" | |
6 | 6" | |
4 | 4" | |
5.25 | 5 1/4" |
Water_Hydrant_Service_Diameter
List of hydrant service sizes, in Imperial units
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
4 | 4" | |
4.5 | 4 1/2" | |
5.25 | 5 1/4" | |
6 | 6" | |
8 | 8" | |
10 | 10" |
Water_Main_Diameter
List of transmission main sizes, in Imperial units
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
4 | 4" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
15 | 15" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
24 | 24" | |
30 | 30" | |
36 | 36" | |
40 | 40" | |
42 | 42" | |
48 | 48" | |
54 | 54" | |
60 | 60" | |
66 | 66" | |
72 | 72" | |
75 | 75" |
Water_Main_Material
Materials for water mains
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
81 | Asbestos Cement - AC | |
82 | Brick - BR | |
83 | Cast Iron - CAS | |
84 | Copper - COP | |
85 | Concrete (Non-Reinforced) - CP | |
86 | Concrete Segments (Bolted) - CSB | |
87 | Concrete Segments (Unbolted) - CSU | |
88 | Ductile Iron - DIP | |
89 | Galvanized Pipe - GP | |
90 | Pitch Fiber (Orangeburg) - OB | |
91 | Plastic/Steel Composite - PSC | |
92 | Polyethylene - PE | |
93 | Polypropylene - PP | |
94 | Polyvinyl Chloride - PVC | |
95 | Steel - SP | |
96 | Transite - TTE | |
97 | Wood - WD | |
98 | Pre-stressed Concrete Cylinder Pipe - PCCP | |
99 | Pre-stressed Concrete Embedded Cylinder Pipe AWWA C-301 - PCPE | |
100 | Pre-stressed Concrete Lined Cylinder Pipe AWWA C-301 - PCPL | |
101 | Steel Cylinder Reinforced Concrete Pipe - SRC | |
102 | High Density Polyethylene - HDPE | |
103 | Unreinforced Concrete Pipe - URC | |
104 | Fiberglass Reinforced Pipe - FRP | |
105 | Reinforced Concrete Pipe - RCP | |
106 | Corrugated Pipe - CORR | |
107 | Plastic - PLA | |
108 | Non-Plastic - NPLA |
Water_Meter_Diameter
General list of service sizes, in Imperial units
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.25 | 2 1/4" | |
2.5 | 2 1/2" | |
3 | 3" | |
4 | 4" | |
4.5 | 4 1/2" | |
5.25 | 5 1/4" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
0.5 | 1/2" | |
0.625 | 5/8" | |
12 | 12" | |
14 | 14" | |
15 | 15" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
24 | 24" |
Water_Pump_Diameter
Sizes of pumps
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
4 | 4" | |
6 | 6" | |
8 | 8" | |
10 | 10" | |
12 | 12" | |
14 | 14" | |
15 | 15" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
24 | 24" | |
36 | 36" | |
48 | 48" |
Water_Pump_Type
The different types of pump designs.
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
40 | Axial Flow | |
41 | Centrifugal | |
42 | Jet | |
43 | Reciprocating | |
44 | Rotary | |
45 | Turbine |
Water_Service_Diameter
General list of service sizes, in Imperial units
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
0.5 | 1/2" | |
0.75 | 3/4" | |
1 | 1" | |
1.25 | 1 1/4" | |
1.5 | 1 1/2" | |
2 | 2" | |
2.25 | 2 1/4" | |
2.5 | 2 1/2" | |
3 | 3" | |
4 | 4" | |
4.5 | 4 1/2" | |
5.25 | 5 1/4" | |
6 | 6" | |
8 | 8" | |
10 | 10" |
Water_Service_Material
Materials for water service lines
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
83 | Cast Iron - CAS | |
84 | Copper - COP | |
88 | Ductile Iron - DIP | |
94 | Polyvinyl Chloride - PVC | |
109 | Lead - LP |
Water_Type
List of water types
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Potable | |
2 | Irrigation | |
3 | Fire | |
4 | Raw |
Water_Valve_Surface_Type
Surface types used in valve inspection
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Asphalt | |
2 | Brick | |
3 | Concrete | |
4 | Dirt | |
5 | Grass | |
6 | Gravel | |
7 | Other |
Water_Valve_Type
Types of controllable water valves
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
20 | Ball | |
21 | Butterfly | |
22 | Cone | |
23 | Gate | |
24 | Plug |
Water_Well_Diameter
General list of well sizes
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
DOUBLE | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
10 | 10" | |
14 | 14" | |
16 | 16" | |
18 | 18" | |
20 | 20" | |
30 | 30" |
Yes_No
Valid Yes, No values
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Yes | |
2 | No |
Yes_No_Not_Applicable
Valid Yes, No, and NA values
Domain Details
Type | Split Policy | Merge Policy |
---|---|---|
SHORT | DUPLICATE | DEFAULT |
Domain Values
Code | Value | Description |
---|---|---|
0 | Unknown | |
1 | Yes | |
2 | No | |
3 | N/A |